Browse all practice questions for the National Grid Task 70 Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

National Grid Task 70 Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • During an explosion on site, whom should you check in with on scene?
  • What term describes a condition identified by the operator that may indicate a malfunction or deviation from normal operations and could pose hazards?
  • Because of its weight, which substance mixes with air?
  • What does the FLONC acronym stand for in gas hazard awareness?
  • Carbon monoxide is a byproduct of _______________________.
  • Which step is explicitly listed as part of the response to a component failure?
  • By compressing natural gas, it increases its ______ and ______.
  • What distance constitutes the standard safe perimeter during a component failure?
  • During a gas leak, what step helps protect the public?
  • What actions are required in the event of an explosion?
  • If re-entry into a confined space is necessary after atmospheric testing, what is required?
  • What is the flammability range percentage for gas?
  • If a hazardous atmosphere is present, what procedure should be followed?
  • What is the best immediate action during an uncontrolled ignition of gas?
  • If a meter is full of water, what is the proper action?
  • In an area where gas is blowing but there is no odor, this could indicate what?
  • Natural gas expands when heated and contracts when cooled. Which answer option captures this correctly?
  • In responding to a gas leak, which action is critical to reduce ignition risk?
  • What is the primary safety objective when gas facility damage is discovered?
  • During a gas incident, which action is required to coordinate on-scene operations?
  • What is the correct action when a gas explosion occurs?
  • What is the first safety action if the atmosphere in a confined space becomes unsafe?
  • If facilities are unintentionally exposed, what action should you take?
  • If there are reports of customers having no gas, what are two possible main issues?
  • Which statement correctly describes what you should do when you detect inadequate transmission pressure?
  • What are the signs of a gas leak?
  • During inadequate transmission pressure, which condition would be unsafe?
  • What do construction equipment, trucks, vehicles and static electricity all contribute ignition of?
  • PCB waste disposal location?
  • Which gas is likely to accumulate near the ceiling in an enclosed space due to being lighter than air?
  • When natural gas is compressed, which pair increases?
  • For odor complaint investigations, which phrase describes the required protocol?
  • Mercaptan is added for what reason?
  • What defines excessive pressure in a gas system?
  • Natural gas is what?
  • When inadequate transmission pressure is detected, what is the recommended sequence of actions?
  • What is required when investigating all odor complaints?
  • If improper odorization is found, what steps should you follow?
  • What is the flammability range of natural gas?
  • Methane constitutes approximately what percentage of natural gas?
  • When damage to gas facilities is observed, which sequence best reflects the recommended actions?
  • Which action is a safety-focused step during a component failure?
  • If there is atmospheric change in a confined space, what steps should you follow?
  • What should you do if unintentional ignition occurs?
  • During an environmental incident who should you contact?
  • When gas is blowing but there is no odor, the system may be described as what?
  • What should you do if a relief valve is blowing?
  • If you have gauges or telemeters indicating a lower pressure than normal this would be a ________________?
  • What defines inadequate pressure, and what action is associated with bagging?
  • If there is an explosion in a manhole, it is generally assumed that __________________________.
  • What is an environmental incident?
  • Which action is not listed as part of the environmental incident response?
  • When there is no gas detected, which action should you take?
  • The principal component in natural gas is methane. Which is a correct option for its typical composition?
  • What can gas facilities be damaged by?
  • Which of the following best indicates damaged gas pipes?
  • Which material does not erode in this context?
  • Which statement about gas piping materials is true?
  • When natural gas is heated, what happens to its volume?
  • In a street where flooding occurs and a high-pressure gas leak is present, what two hazards are likely?
  • Above normal pressure at a _________________ could be the cause for the regulator to _____________
  • If you detect a gas odor, what is the most appropriate initial action?
  • What do you do if you found a dent in a pipe?
  • What is the main component found in natural gas and approximately what percentage is it?
  • If a relief valve is blowing, what should you avoid doing with valves?
  • What is the risk associated with blowing gas on both plastic and steel mains/services?
  • Blowing gas can be identified as which of the following?
  • Adequate pressure is greater than which range?
  • Gas leaks can show signs even without odor. Which sign would indicate this?
  • What do you do if a gas explosion occurs ?
  • Which two materials are treated the same and have the same potential to ignite blowing gas when ruptured?
  • Natural gas is ______ than air, with a specific gravity of approximately ______.
  • Which of the following sets correctly lists the properties of natural gas?
  • What do you do if you find PCB at a worksite?
  • What is the recommended action when you uncover a damaged facility?
  • During an uncontrolled escape of gas while performing a covered task, which action should be taken to address ignition sources?
  • What should you do if you uncover a damaged facility?
  • Which of the following is NOT part of the recommended response to a component failure?
  • What do you do if you're on a call and a higher than expected reading is found?
  • If damage occurs to facilities, which actions should you take?
  • Which statement best describes the odorization status when gas is blowing and no odor is detected?
  • Which action is part of responding to an environmental incident?
  • Which step should be taken before reentering a confined space after an atmosphere change?
  • Which term describes a pressure reading that is lower than expected?
  • The abbreviation AOC stands for which term?
  • Gas flows from which type of pressure to which?
  • 0-124 PSIG is associated with which part of the gas system?
  • When natural gas is cooled, what happens to its volume?
  • After a component failure, which assessment step should be performed to check gas levels?
  • Why is natural gas called the silent killer?
  • If a gas system is over-pressurized, which indication would generally be present?
  • In a natural gas system, from which pressure to which pressure does the gas flow?
  • In response to an unintentional ignition, which two contacts must be made immediately?
  • Which of the following would be an immediate priority when an inadequate pressure condition is observed?
  • What perimeter should be maintained during a component failure?
  • During a component failure, what is the primary action you should take to ensure safety?
  • If pressurization occurs at the gate station where odorizing is performed, what is a possible cause?
  • Which action is used to evaluate the hazard level after a component failure?
  • What instruments are required when determining adequate pressure?
  • What color is the flame when burning clean natural gas?
  • If there are reports of customers having no gas, what could be the cause?
  • If a regulator is venting gas, what should you do?
  • Lower than normal pressure could be caused by having ________________________.
  • What is a safe distance for the public during an uncontrolled gas escape?
  • Under pressurization, odorizing being left in manual mode is most likely caused by what?